Technical data Cable structure Properties
• Bare copper conductors, extra fine wire
acc. to DIN VDE 0295 cl.6, col. 4,
BS 6360 cl.6 and IEC 60228 cl.6
• Special drag chain cable, twisted in pairs, •
adapted to DIN VDE 0812
Very good oil resistant
• Resistant to weather, ozone, hydrolysis•
Temperature range and UV-radiation
flexing -30°C to +70°C
fixed installation -40°C to +70°C
• Core insulation of PP • Chemical resistant to solvents, acids, lyes
• Core identification to DIN 47100 and hydraulic liquidity
• Guaranteed permanent application in
multi-shift operation under extreme high
bending stress
• Nominal voltage
350 V
• Cores twisted in pairs, the pairs torsion-free
stranded in layers
• Test voltage
1500 V
• Special fleece over outer layer
• Tinned copper screened braiding, • High resistant to mechanical strain
• Insulation resistance approx. 85% coverage • High property of alternating bending strength
min. 100 MOhm x km • Long life durabilities through low
friction-resistance by using the PP-core
insulation where the core are stranded in
layers
• Outer sheath of full-polyurethane
compound type TMPU to
DIN VDE 0207-363-10-2 /
DN EN 50363-10-2
• Mutual capacitance
approx. 135 nF/km
• Minimum bending radius
flexing
at 0,25 mm²: 7,5x cable Ø
at 0,5 - 1 mm²: 10x cable Ø
fixed installation
at 0,25 mm²: 4x cable Ø
at 0,5 - 1 mm²: 5x cable Ø
• High tensile strength-, abrasion- and impact
resistant at low temperature
• Sheath colour: grey (RAL 7001)
• With meter marking
• Adhesion-low
• The materials used during manufacturing
are cadmium-free, contain no silicone
and are free from substances harmful
• Coupling resistance to the wetting properties of lacquers
max. 250 Ohm/km
• Radiation resistance Note
up to 100x106 cJ/kg (up to 100 Mrad) • AWG sizes are approximate equivalent
values. The actual cross section is in mm